Maximum speed | 2.0 m/s (7.2 km/h) | 6.6 ft/s (4.4 mph) |
Operational corridor width | With default setup: 1 450 mm | 57 in With improved setup: 850 mm | 33.5 in |
Operational corridor width for two robots passing | With default setup: 3 200 | 126 in
With improved setup: 1 700 mm | 67 in |
Positioning accuracy (in controlled conditions) | Docking to VL-marker: ± 3 mm | 0.12 in on X-axis, ± 3 mm | 0.12 in on Y-axis
Moving to position: ± 60 mm | 2.36 in on X-axis, ± 85 mm | 3.35 in on Y-axis |
Traversable gap tolerance | Up to 20 mm | 0.79 in |
Operational doorway width | With default setup: 1 300 mm | 51.2 in
With improved setup: 750 mm | 29.5 in |
Active operation time with maximum payload | Up to 13 h |
Active operation time with no payload | Up to 17.4 h |